# This evafilter.txt file CVS Revision is 1.22                          |
#									|
# The format of the EVA Event Code values used for WEBES EVA HSV	|
# filtering contained in this file is as follows:			|
#									|
# The filter number  "0xAABBCCDD" is the complete VCS Event Code.	|
# 									|
# Where:  AA = SCID							|
#	  BB = EIP_event_number						|
#	  CC = CAC							|
#	  DD = EIP_type_code						|
#									|
# They are located in, and extracted from the EIP_Common_Prefix frame 	|
# of the event log							|
#									|
# In the following list of EVA event codes, two comment characters      |
# are used to separate the event code from the corresponding text.      |
# When the pound sign (#) is used, this event will be processed by      |
# the analysis rules.  When the at sign (@) is used, the event will     |
# not be processed, but the text following the event code will be       |
# with the event in the event summary.                                  |
#                                                                       |
# An additional feature is that the <FONT COLOR=...></FONT> tags        |
# should be recognized by supported browers with the affect of          |
# displaying the event text in the specified color in the Summary       |
# section.                                                              |
#                                                                       |
# Color Legend:                                                         |
#                                                                       |
#    red         = Significant events                                   |
#    green       = Configuration events and return to normal status     |
#                  from a previous failure                              |
#    blue        = EVA Reboot/Resync/Restart, etc.                      |
#    darkorange  = Data Availability, CA, Customer attention needed     |
#    magenta     = Drive firmware update events                         |
#    purple      = Thresholded events                                   |
#                                                                       |
#************************************************************************
#Revision History
#
#	Randy Wolf 	Added DRM events 0x0c17630c/	V1.120	01-Sep-04
#			0x0c18640c/0x0c1b5f0c/0x0c1c610c/
#			and 0x0c1e5f0c.  All of which are set 
#			as "analyzable".
#
#	Randy Wolf 	Added events 0x0300200a 	V1.120	02-Sep-04
#			and 0x0b01b515.  Both of which 
#			are set as "analyzable".
#	Randy Wolf	Enabled event 0x09d50005 per
#			Roy Carlson's request
#	Randy Wolf	Enabled events 0x0c22000c/ 	V1.22	14-Dec-04
#			0x0c23670c/ and 0x4206001b
#			as required to support VCS V3025
#	Randy Wolf	Enabled event 0x0c1a000c	V1.23	15-Dec-04
#			as required to support VCS V3025
#	Randy Wolf	Disabled event 0x4206001b.	V1.24	15-Dec-04
#			Will not analyze event
#	Roy Carlson	Turned on 0x06120008		V1.25	13-Jan-05
#
#
#
#------------------------------------------------------------------------
#  The Executive Services (EXEC) events are:
#
0x0100000d@-EXEC During Executive Services initialization the system time value was set.
0x0101000d@-EXEC The system time value was set by a call to the EXEC$SET_TIME service.
0x0102000d@-EXEC A time change occurred.
#
#------------------------------------------------------------------------
#  The Storage System Services events are:
#
0x0300000a#-<FONT COLOR=red>SCS A controller can't communicate with the CBIC</FONT>
0x0300200a#-<FONT COLOR=red>SCS A controller can't communicate with the CBIC</FONT>
0x0301400b#-<FONT COLOR=red>SCS Disk rendered inoperable</FONT>
0x0302410a#-<FONT COLOR=red>SCS Disk won't be used because it represents "too many"</FONT>
0x03024f0b#-<FONT COLOR=red>SCS Disk won't be used because it represents "too many"</FONT>
0x0303000a#-<FONT COLOR=blue>SCS A controller has begun booting</FONT>
#
0x0304000a@-SCS A controller has finished the process of bringing the Storage System online.
0x0305000a@-SCS A controller has been joined into the Storage System.
0x0306000a@-SCS A controller has been ousted from the Storage System.
0x0307000a@-SCS A controller is now the Storage System Master.
0x0308000a@-SCS A controller has been brought into the Storage System.
#
#------------------------------------------------------------------------
#  The Fault Manager (FM) events are:
#
0x04000300#-<FONT COLOR=blue>FM Termination Events (the controller reporting itself)</FONT>
0x04010300#-<FONT COLOR=blue>FM Last Gasp Termination Events (the other controller reporting)</FONT>
0x04020101#-<FONT COLOR=blue>FM Machine check while a Termination event was processed</FONT>
0x04030102#-<FONT COLOR=blue>FM Unexpected event while a Termination event was processed</FONT>
0x04060803#-<FONT COLOR=blue>FM Insufficient Event Log Packets on the Master</FONT>
0x04060103#-<FONT COLOR=blue>FM Insufficient Event Log Packets on the Master</FONT>
0x04070803#-<FONT COLOR=blue>FM Insufficient Event Log Packets on the non-Master</FONT>
0x04070103#-<FONT COLOR=blue>FM Insufficient Event Log Packets on the non-Master</FONT>
0x040c0103#-<FONT COLOR=blue>FM Invalid EIP from remote Fault Manager</FONT>
0x040c0803#-<FONT COLOR=blue>FM Invalid EIP from remote Fault Manager</FONT>
0x040e0300#-<FONT COLOR=blue>FM Last Gasp that indicates the other should terminate operation</FONT>
0x04100103#-<FONT COLOR=blue>FM Insufficient ISR Event Log Packets on the Master</FONT>
0x04100803#-<FONT COLOR=blue>FM Insufficient ISR Event Log Packets on the Master</FONT>
0x04110103#-<FONT COLOR=blue>FM Insufficient ISR Event Log Packets on the non-Master</FONT>
0x04110803#-<FONT COLOR=blue>FM Insufficient ISR Event Log Packets on the non-Master</FONT>
#
0x04040003@-FM The Storage System Event Log validation completed successfully.
0x04050003@-FM The Storage System Event Log validation failed.
0x04080003@-FM The Storage System Termination Event Log has become inaccessible.
0x04090003@-FM The Storage System Termination Event Log validation completed successfully.
0x040a0003@-FM The Storage System Termination Event Log validation failed.
0x040b0003@-FM The Termination Event Log has been updated with event information from the secondary controller.
0x040d0003@-FM The Fault Manager operation was made quiescent.
0x040f0003@-FM This controller sent its termination events to the Master controller.
0x04120003@-FM The last event reporting interval has changed or last event reporting has been enabled or disabled.
0x04130003@-FM Storage System event reporting is still active.
#
#------------------------------------------------------------------------
#  The Fibre Channel Services (FCS) events are:
#
0x06004009#-<FONT COLOR=red>FCS Exceeded SMART threshold</FONT>
0x06000009@-<FONT COLOR=red>FCS Exceeded SMART threshold</FONT>
#
0x06014a08#-<FONT COLOR=red>FCS Fibre Channel port failed to respond</FONT>
0x06080007#-<FONT COLOR=purple>FCS Excessive link errors on a Fibre Channel port</FONT>
#
0x06020009#-<FONT COLOR=purple>A drive has reported a check condition error</FONT>
0x061c4709#-<FONT COLOR=purple>FCS Outbound frame timed out</FONT>
#
0x06034713@-<FONT COLOR=purple>FCS Exchange timed out</FONT>
0x06044812@-<FONT COLOR=purple>FCS Unexpected work</FONT>
0x06054909@-<FONT COLOR=purple>FCS Disk or MP didn't respond</FONT>
0x06074709@-<FONT COLOR=purple>FCS Target Discovery Service Descriptor timed out</FONT>
0x060b4709@-<FONT COLOR=purple>FCS Non-data exchange has timed out</FONT>
0x061d4709@-<FONT COLOR=purple>FCS Exchange to a disk finished, but is missing data</FONT>
#
0x06094013#-<FONT COLOR=red>FCS Numerous SMART errors</FONT>
0x06090013@-<FONT COLOR=red>FCS Numerous SMART errors</FONT>
#
0x060a0013#-<FONT COLOR=purple>FCS A drive has reported numerous check condition errors</FONT>
0x060c0013#-<FONT COLOR=green>FCS Loop switch detected</FONT>
0x060e9613#-<FONT COLOR=red>FCS EMU Firmware update not found</FONT>
0x060f4013#-<FONT COLOR=red>FCS EMU can communicate to drive, but controller can't</FONT>
0x06108913#-<FONT COLOR=red>FCS Controller can't communicate with EMU</FONT>
0x06109b13#-<FONT COLOR=red>FCS Controller can't communicate with EMU</FONT>
0x06130013#-<FONT COLOR=green>FCS Controller to EMU communication restored</FONT>
0x06149813#-<FONT COLOR=green>FCS Too many drive enclosures</FONT>
0x06159913#-<FONT COLOR=green>FCS FC Cable is connected to the wrong FC port</FONT>
0x06169713#-<FONT COLOR=green>FCS Controller doesn't have an address on the CAN bus</FONT>
0x06174013#-<FONT COLOR=red>FCS The EMU has bypassed a drive</FONT>
#
0x061a4009#-<FONT COLOR=red>FCS Disk exceeded soft error threshold</FONT>
0x061a0009@-<FONT COLOR=red>FCS Disk exceeded soft error threshold</FONT>
#
0x061e4c13#-<FONT COLOR=red>FCS Controller has detected only one port on a device</FONT>
0x061f0013@-<FONT COLOR=green>FCS Drive Single Port on Fibre fixed</FONT>
#
0x06304e13#-<FONT COLOR=red>FCS All devices in an enclosure are Single Port on Fibre</FONT>
0x06310013@-<FONT COLOR=green>FCS Enclosure Single Port on Fibre fixed</FONT>
#
0x06324e13#-<FONT COLOR=red>FCS All devices on a loop are Single Port on Fibre</FONT>
0x06330013@-<FONT COLOR=green>FCS Loop Single Port on Fibre fixed</FONT>
#
0x06204013#-<FONT COLOR=red>FCS Unsupported device found</FONT>
0x06220004#-<FONT COLOR=magenta>FCS Unrecognized drive or firmware found by code load</FONT>
0x06224d04#-<FONT COLOR=magenta>FCS Unrecognized drive or firmware found by code load</FONT>
#
0x06254313#-<FONT COLOR=red>FCS EMU failed to assign a hard address to a drive</FONT>
0x06268913#-<FONT COLOR=red>FCS EMU failed to assign an address to a drive</FONT>
0x06270113#-<FONT COLOR=red>FCS EMU failed to assign address(s) to a drive</FONT>
0x062b4004#-<FONT COLOR=red>FCS Drive was bypassed</FONT>
#
0x06354d04#-<FONT COLOR=magenta>FCS Unrecognized Fibre Channel drive firmware revision</FONT>
0x06364d04#-<FONT COLOR=magenta>FCS Unsupported Fibre Channel drive firmware revision</FONT>
0x0637c404#-<FONT COLOR=magenta>FCS Newer than supported Fibre Channel drive firmware revision</FONT>
0x0638c404#-<FONT COLOR=magenta>FCS Down-rev Fibre Channel drive firmware revision</FONT>
0x06404d04#-<FONT COLOR=magenta>FCS A disk that has new capabilities has been detected.</FONT> 
#
0x06390009#-<FONT COLOR=red>FCS A drive bay was bypassed to restore operability</FONT>
0x06394009#-<FONT COLOR=red>FCS A drive bay was bypassed to restore operability</FONT>
#
0x063a0008@-<FONT COLOR=red>FCS The controller is attempting to recover devices</FONT>
0x063b0008@-<FONT COLOR=red>FCS The controller has finished error recovery attempts</FONT>
0x063c0008@-<FONT COLOR=green>FCS The controller has been requested to unbypass bays on a port</FONT>
#
0x063d9b09#-<FONT COLOR=red>FCS An enclosure on the cabinet address bus has no Fibre Channel connection</FONT>
0x063ec513#-<FONT COLOR=red>FCS An enclosure was found on Fibre Channel, but not on the cabinet address bus</FONT>
0x063f9c13#-<FONT COLOR=red>FCS A disk is using an improper protocol to attempt communication with an EMU</FONT>
#
0x060d0013@-FCS The location of a disk previously reported as unknown is now known.
0x06120008#-FCS The retry count for a task assigned to a EMU has been exhausted.
0x06180013@-FCS An EMU has begun updating its code.  Do not power down the enclosure until the code update is done.
0x06190013@-FCS An EMU has completed updating its code.  It is now safe to power down this drive enclosure.
0x061b0013@-FCS A controller now has an address on the enclosure address bus.
0x06210013@-FCS A Fibre Channel device with incorrect block size has been detected.
0x06230013@-FCS A controller is about to retry a failed port.
0x06240013@-FCS A controller has successfully retried a failed port.
0x06280008@-FCS The retry count for an OB task assigned to a EMU has been exhausted.
0x06290009@-FCS The controller has sent a Basic Link Service command Abort Sequence Frame.
0x062a0009@-FCS The controller has sent an Extended Link Service command Reinstate Recovery Qualifier.
0x062c0012@-FCS One or more media defects were detected on a physical disk drive.
0x062d0012@-FCS A controller issued a directed LIP to an arbitrated loop physical address.
0x062e0012@-FCS A controller has detected loop receiver failures.
0x06340013@-FCS A controller has been told to enable a device port, that was not disabled during boot diagnostics.
0x06410017@-FCS The device loop configuration has changed on a controller's Fibre Channel port.
#
#--------------------------------------------------------------------------
#  The Container Services events are:
#
0x0700b515#-<FONT COLOR=darkorange>EXEC Allocation of a Virtual Disk stalled; out of space.</FONT>
0x0701b515#-<FONT COLOR=darkorange>EXEC Expansion of a Virtual Disk stalled; out of space.</FONT>
0x0b01b515#-<FONT COLOR=darkorange>EXEC A migrate method drive codeload has stalled.</FONT>
#
0x07050015@-<FONT COLOR=green>CS A member management operation has finished</FONT>
0x0709b515@-<FONT COLOR=darkorange>CS A member management operation has stalled; out of space</FONT>
#
0x07020015@-CS Leveling of capacity in a Disk Group has started.
0x07030015@-CS Leveling of capacity in a Disk Group has finished.
0x07040015@-CS A member management operation has started due to the appearance or disappearance of a disk.
0x07060015@-CS Data Migration has started on a Disk Group.
0x07070015@-CS Data migration has finished on a Disk Group.
0x07080015@-CS Deallocation of a Virtual Disk has failed.
0x070a0015@-CS A stalled member management operation is being restarted.
0x070b0015@-CS Unexpected metadata utility event.
#
#--------------------------------------------------------------------------
#  The Storage System Management Interface (SCMI) event are:
#
0x09020005#-<FONT COLOR=green>SCMI Volume condition changed; no action required</FONT>
0x0906bf05#-<FONT COLOR=darkorange>SCMI Volume Missing</FONT>
0x09144005#-<FONT COLOR=red>SCMI Volume Failed</FONT>
0x0914bf05#-<FONT COLOR=red>SCMI Volume Failed</FONT>
#
0x0908b405#-<FONT COLOR=darkorange>SCMI Occupancy Alarm Level threshold has been reached</FONT>
0x091c0005#-<FONT COLOR=green>SCMI Occupancy Alarm Level Normal</FONT>
#
0x090e2e05#-<FONT COLOR=red>SCMI Temperature trip point has been reached</FONT>
0x090e3605#-<FONT COLOR=red>SCMI Temperature trip point has been reached</FONT>
0x090f2e05#-<FONT COLOR=darkorange>SCMI Temperature nearing trip point</FONT>
0x09160005#-<FONT COLOR=green>SCMI Temperature returned to normal</FONT>
#
0x09130005#-<FONT COLOR=red>SCMI Voltage sensor detected voltage out-of-range</FONT>
0x09132005#-<FONT COLOR=red>SCMI Voltage sensor detected voltage out-of-range</FONT>
#
0x0915b905#-<FONT COLOR=red>SCMI Controller Failed</FONT>
0x09040005#-<FONT COLOR=green>SCMI Controller Normal</FONT>
#
0x091a2f05#-<FONT COLOR=red>SCMI Battery voltage regulator is offline</FONT>
0x091a2005#-<FONT COLOR=red>SCMI Battery voltage regulator is offline</FONT>
#
0x09172805#-<FONT COLOR=red>SCMI Battery #1 has been removed</FONT>
0x091f2905#-<FONT COLOR=red>SCMI Battery #2 has been removed</FONT>
0x091e0005#-<FONT COLOR=green>SCMI Battery #1 is present</FONT>
0x09200005#-<FONT COLOR=green>SCMI Battery #2 is present</FONT>
#
0x091d2205#-<FONT COLOR=red>SCMI Battery #1 has malfunctioned</FONT>
0x09222305#-<FONT COLOR=red>SCMI Battery #2 has malfunctioned</FONT>
0x09180005#-<FONT COLOR=green>SCMI Battery #1 is normal</FONT>
0x09210005#-<FONT COLOR=green>SCMI Battery #2 is normal</FONT>
#
0x09d22a05#-<FONT COLOR=red>SCMI Blower #1 has been removed</FONT>
0x09232b05#-<FONT COLOR=red>SCMI Blower #2 has been removed</FONT>
0x09110005#-<FONT COLOR=green>SCMI Blower #1 is present</FONT>
0x09240005#-<FONT COLOR=green>SCMI Blower #2 is present</FONT>
#
0x09122405#-<FONT COLOR=red>SCMI Blower #1 is too slow</FONT>
0x09da0005@-<FONT COLOR=green>SCMI A controller's blower "1" is running at normal speed.</FONT>
0x09252505#-<FONT COLOR=red>SCMI Blower #2 is too slow</FONT>
0x09db0005@-<FONT COLOR=green>SCMI A controller's blower "2" is running at normal speed.</FONT>
#
0x09262c05#-<FONT COLOR=red>SCMI Blower/Power Supply #1 has been removed or lost power</FONT>
0x09282d05#-<FONT COLOR=red>SCMI Blower/Power Supply #2 has been removed or lost power</FONT>
0x09270005#-<FONT COLOR=green>SCMI Blower/Power Supply #1 is present</FONT>
0x09290005#-<FONT COLOR=green>SCMI Blower/Power Supply #2 is present</FONT>
#
0x092a2605#-<FONT COLOR=red>SCMI Blower/Power Supply #1 is too slow</FONT>
0x092b2705#-<FONT COLOR=red>SCMI Blower/Power Supply #2 is too slow</FONT>
#
0x092c2f05#-<FONT COLOR=red>SCMI Battery hold-up time is zero hours</FONT>
0x09050005#-<FONT COLOR=green>SCMI Battery hold-up time is > 0 hours</FONT>
#
0x092dbf05#-<FONT COLOR=darkorange>SCMI Volume Resource Availability Insufficient</FONT>
0x09090005#-<FONT COLOR=green>SCMI Volume Resource Availability Sufficient</FONT>
#
0x09300005#-<FONT COLOR=red>SCMI Physical drive map has been updated</FONT>
#
0x0942500e#-<FONT COLOR=darkorange>SCMI Snapshot marked inoperative due to insufficient space</FONT>
#
0x0946000e#-<FONT COLOR=green>SCMI A Data Replication Group has been created</FONT>
0x0978000f#-<FONT COLOR=green>SCMI A Data Replication Group has been suspended or resumed</FONT>
#
0x09c85105#-<FONT COLOR=darkorange>SCMI Logical Disk Data Availability state is Data Lost</FONT>
0x090a0005#-<FONT COLOR=green>SCMI Logical Disk Data Availability state is Normal</FONT>
#
0x09030005#-<FONT COLOR=green>SCMI Logical Disk state changed; no action required</FONT>
0x09ca5105#-<FONT COLOR=red>SCMI Logical Disk state is Failed</FONT>
0x09cc5105#-<FONT COLOR=red>SCMI Logical Disk state is Data Lost</FONT>
0x09cb5005#-<FONT COLOR=red>SCMI Logical Disk state is Snapshot Overcommit</FONT>
#
0x091b0005#-<FONT COLOR=green>SCMI Disk Group state is Normal</FONT>
0x09c95105#-<FONT COLOR=red>SCMI Disk Group state is INOPERATIVE</FONT>
0x09ce0005#-<FONT COLOR=darkorange>SCMI Disk Group state is INOPERATIVE MARKED</FONT>
#
0x09070005#-<FONT COLOR=green>SCMI Fibre Channel port NORMAL</FONT>
#
0x09010005#-<FONT COLOR=green>SCMI Physical Disk Drive state is Normal</FONT>
0x09314205#-<FONT COLOR=red>SCMI Physical Disk Drive state is Degraded</FONT>
0x09324005#-<FONT COLOR=red>SCMI Physical Disk Drive state is Failed</FONT>
0x09cf4105#-<FONT COLOR=red>SCMI Physical Disk Drive state is Not Present</FONT>
#
0x093e420e#-<FONT COLOR=red>SCMI Physical Disk Drive state is Disappeared</FONT>
0x0936000e#-<FONT COLOR=green>SCMI Physical Disk Drive has been Discovered</FONT>
#
0x09d1b905@-<FONT COLOR=red>SCMI The HSV controller needs attention</FONT>
0x09d00005@-<FONT COLOR=green>SCMI The HSV controller no longer needs attention</FONT>
#
0x09d60005#-<FONT COLOR=red>SCMI Temperature sensors do not agree</FONT>
0x09d63705#-<FONT COLOR=red>SCMI Temperature sensors do not agree</FONT>
0x09d70005#-<FONT COLOR=red>SCMI Temperature sensors can not be accessed</FONT>
0x09d73705#-<FONT COLOR=red>SCMI Temperature sensors can not be accessed</FONT>
#
0x09d35105@-<FONT COLOR=red>SCMI A Virtual Disk in the DR Group is Inoperative</FONT>
0x09d50005#-<FONT COLOR=red>SCMI Disk is "Single Port on Fibre"</FONT>
0x0970460f@-<FONT COLOR=purple>SCMI Drive has numerous communication failures</FONT>
0x090c0005@-SCMI A snapclone Logical Disk has completed the unsharing operation.
0x090d0005@-SCMI The state of the quorum disk flag of a Volume has changed.
0x09190005@-SCMI A voltage sensor has returned to a normal range.
0x092e0005@-SCMI A controller has rejected a login attempt.
0x092f0005@-SCMI A controller has processed a SCMI command with the result of non-success return code.
0x09cdc305@-<FONT COLOR=red>SCMI Fibre Channel port FAILED</FONT>
0x09d40005@-SCMI All the Virtual Disks associated with a DR Group have transitioned to the OPERATIVE state.
#
0x0933000e@-SCMI A Derived Unit was created.
0x0934000e@-SCMI A Logical Disk was created.
0x0935000e@-SCMI A Disk Group was created.
0x0937000e@-SCMI A Presented Unit was created.
0x0938000e@-SCMI A Storage System Host Path was created.
0x0939000e@-SCMI A Storage System Virtual Disk was created.
0x093a000e@-SCMI A Volume was created.
0x093b000e@-SCMI A Derived Unit was deleted.
0x093c000e@-SCMI A Logical Disk was deleted.
0x093d000e@-SCMI A Disk Group was deleted.
0x093f000e@-SCMI A Presented Unit was deleted.
0x0940000e@-SCMI A Storage System Host Path was deleted.
0x0941000e@-SCMI A Storage System Virtual Disk was deleted.
0x0943000e@-SCMI A controller has joined the Storage System.
0x0945000e@-SCMI The Storage System has been deleted.
0x0947000e@-SCMI A Data Replication Group was deleted.
0x0948000e@-SCMI An internal Logical Disk associated with a snapshot Virtual Disk was created.
0x0949000e@-SCMI An internal Logical Disk associated with a copy of a Virtual Disk was created.
#
0x0944b90e@-<FONT COLOR=blue>SCMI An HSV controller has left the Storage System</FONT>
0x0944ba0e@-<FONT COLOR=blue>SCMI An HSV controller has left the Storage System</FONT>
#
0x0965000f@-SCMI A host operating system mode has changed.
0x0966000f@-SCMI Time was set on a Storage System.
0x0967000f@-SCMI The LUN of a Presented Unit has changed.
0x0968000f@-SCMI The device addition policy of a Storage System has changed.
0x0969000f@-SCMI The quiescent state of a Storage System Virtual Disk has changed.
0x096a000f@-SCMI The enabled/disabled state of a Storage System Virtual Disk has changed.
0x096b000f@-SCMI The cache policy of a Storage System Virtual Disk has changed.
0x096c000f@-SCMI The usage state of a Volume changed.
0x096d000f@-SCMI The disk failure protection level of a Disk Group has changed.
0x096e000f@-SCMI The write protected state of a Derived Unit has changed.
0x0971000f@-SCMI A controller has received a request to shutdown.
0x0972000f@-SCMI A controller has completed its shutdown preparations.
0x0973000f@-SCMI The failsafe state of a Data Replication Group has changed.
0x0974000f@-SCMI The mode of a Data Replication Group has changed.
0x0975000f@-SCMI The synchronous/asynchronous operational state of a Data Replication Group has changed.
0x0976000f@-SCMI The read only attribute of a Data Replication Group has changed.
0x0977000f@-SCMI A Data Replication Group failover has occurred.
0x0979000f@-SCMI A Storage System Virtual Disk was added to a Data Replication Group.
0x097a000f@-SCMI A Storage System Virtual Disk was removed from a Data Replication Group.
#
#---------------------------------------------------------------------------
#  The System Services (SYS) event is:
#
0x0b000010#-<FONT COLOR=red>SYS The controller has begun a resynchronization operation</FONT>
#
#---------------------------------------------------------------------------
#  The Data Replication Manager (DRM) events are:
#
0x0c00000c#-<FONT COLOR=darkorange>DRM Destination Virtual Disk has completed a full copy</FONT>
0x0c015f0c#-<FONT COLOR=darkorange>DRM Source Virtual Disk transitioned to Logging</FONT>
0x0c02610c#-<FONT COLOR=darkorange>DRM Source Virtual Disk transitioned to Logging</FONT>
0x0c03000c#-<FONT COLOR=darkorange>DRM Destination Virtual Disk is Merging</FONT>
0x0c045f0c#-<FONT COLOR=darkorange>DRM The DR Group has entered Failsafe locked</FONT>
0x0c05600c#-<FONT COLOR=darkorange>DRM The DR Group has entered Failsafe locked</FONT>
0x0c06600c#-<FONT COLOR=darkorange>DRM An unrecoverable read error on the Source</FONT>
0x0c075f0c#-<FONT COLOR=darkorange>DRM A Full Copy terminated prior to completion</FONT>
0x0c08610c#-<FONT COLOR=darkorange>DRM A Full Copy terminated prior to completion</FONT>
0x0c09620c#-<FONT COLOR=darkorange>DRM A Data Replication Log has been reset due to space</FONT>
0x0c10000c#-<FONT COLOR=darkorange>DRM A Destination DR Group has been marked for a full copy</FONT>
0x0c155f0c#-<FONT COLOR=darkorange>DRM The Path between this Site and the Alternate Site has closed.</FONT>
0x0c15000c@-<FONT COLOR=darkorange>DRM The Path between this Site and the Alternate Site has closed.</FONT>
#
0x0c17630c#-<FONT COLOR=darkorange>DRM The DRM comm protocol is mismatched between destination and source.</FONT>
0x0c18640c#-<FONT COLOR=darkorange>DRM The DR Destination is limiting replication throughput.</FONT>
0x0c1a000c#-<FONT COLOR=darkorange>DRM Data Replication Manager State Change.</FONT>
0x0c1b5f0c#-<FONT COLOR=darkorange>DRM The DR Group has transitioned to the Logging state.</FONT>
0x0c1c610c#-<FONT COLOR=darkorange>DRM The DR Group has transitioned to the Logging state.</FONT>
0x0c1e5f0c#-<FONT COLOR=darkorange>DRM The Remote Storage System is not accessible.</FONT>
0x0c21660c#-<FONT COLOR=darkorange>DRM Data Replication Manager State Change.</FONT>
0x0c22000c#-<FONT COLOR=darkorange>DRM Data Replication Path has been opened.</FONT>
0x0c23670c#-<FONT COLOR=darkorange>DRM Unacceptable Data replication throughput.</FONT>
#
0x0c0a000c#-DRM A Data Replication Log has been reset due to a Data Replication Group failover.
0x0c0c000c#-DRM A Destination Data Replication Group has successfully completed a Merge.
0x0c0f000c@-DRM A Data Replication Group is no longer in a Failsafe Locked state.
0x0c11000c#-DRM A Virtual Disk is transitioning from Source to Destination due to a DR Group failover.
0x0c12000c@-DRM A DR Group is transitioning from Destination to Source.
0x0c160016@-DRM A controller has sent a time report message to this controller.
#
#---------------------------------------------------------------------------
#  The Drive Enclosure Environmental Monitoring Unit (EMU) events are:
#
0x0d000111#-<FONT COLOR=red>EMU Unrecognized EMU Event</FONT>
0x0d014011#-<FONT COLOR=red>EMU Non-Fibre Channel drive or incompatible link rate</FONT>
0x0d024111#-<FONT COLOR=red>EMU Drive improperly installed or missing</FONT>
0x0d034111#-<FONT COLOR=red>EMU Drive removed; drive locking enabled on non-locking enclosure</FONT>
0x0d044211#-<FONT COLOR=red>EMU Drive operating at different loop link rate</FONT>
0x0d330911#-<FONT COLOR=red>EMU AC power has been lost</FONT>
0x0d348011#-<FONT COLOR=red>EMU Power Supply improperly installed or missing</FONT>
0x0d358111#-<FONT COLOR=red>EMU Power Supply has failed</FONT>
0x0d359a11#-<FONT COLOR=red>EMU Power Supply has failed</FONT>
0x0d478311#-<FONT COLOR=red>EMU Blower not operating properly</FONT>
0x0d4b8211#-<FONT COLOR=red>EMU Blower improperly installed or missing</FONT>
0x0d4c8411#-<FONT COLOR=red>EMU Both blowers missing</FONT>
0x0d5b8611#-<FONT COLOR=red>EMU Temperature out of range</FONT>
0x0d5f8711#-<FONT COLOR=red>EMU 2 of 3 temperature groups exceed critical</FONT>
0x0d6f8811#-<FONT COLOR=red>EMU Internal EMU Error</FONT>
0x0d728a11#-<FONT COLOR=red>EMU EMU can't collect data for the SES page</FONT>
0x0d7e8c11#-<FONT COLOR=red>EMU Invalid data read from EMU NVRAM</FONT>
0x0d7f8b11#-<FONT COLOR=red>EMU Internal EMU Error</FONT>
0x0d828e11#-<FONT COLOR=red>EMU Enclosure has no address or address is incorrect</FONT>
0x0d838911#-<FONT COLOR=red>EMU EMU hardware failure</FONT>
0x0d858f11#-<FONT COLOR=red>EMU Power Supply didn't shutdown</FONT>
0x0d8d9011#-<FONT COLOR=red>EMU Transceiver error</FONT>
0x0da18111#-<FONT COLOR=red>EMU Power Supply voltage out of range</FONT>
0x0db58111#-<FONT COLOR=red>EMU Power Supply current out of range</FONT>
0x0dd89211#-<FONT COLOR=red>EMU Enclosure invalid NVRAM read error</FONT>
0x0dd99111#-<FONT COLOR=red>EMU Enclosure backplane error</FONT>
0x0ddd9311#-<FONT COLOR=red>EMU I/O Module error</FONT>
0x0dde9511#-<FONT COLOR=red>EMU I/O Module can't communicate with EMU</FONT>
0x0dec9411#-<FONT COLOR=red>EMU I/O Module invalid NVRAM read error</FONT>
#
0x0d710011@-EMU An internal EMU error has occurred.
0x0df00011@-EMU The status has changed on one or more of the drive enclosures.
#
#---------------------------------------------------------------------------
#   The Host Port (HP) event is:
#
0x42000008#-<FONT COLOR=darkorange>Host Port Fibre Channel link is down</FONT>
0x42010008#-<FONT COLOR=darkorange>Host Port Fibre Channel link failed</FONT>
0x42030007#-<FONT COLOR=darkorange>Host Port Fibre Channel link has excessive errors</FONT>
0x42044a08#-<FONT COLOR=red>Host Port Fibre Channel port failed to respond</FONT>
#
0x42000006@-Host Port Fibre Channel link is down
0x42010006@-Host Port Fibre Channel link failed
0x42050008@-Host Port Fibre Channel port has transitioned to the link wedged state.
#
#---------------------------------------------------------------------------
#   The Diagnostic Operations Generator (DOG) event is:
#
0x83002014#-<FONT COLOR=red>Diag On-board diagnostic failed</FONT>
0x83013014#-<FONT COLOR=red>Diag GBIC SSF Serial ID Data check code failure</FONT>
0x83022214#-<FONT COLOR=red>Diag Battery assembly failure: Battery #1</FONT>
0x83032314#-<FONT COLOR=red>Diag Battery assembly failure: Battery #2</FONT>
0x83043114#-<FONT COLOR=red>Diag Battery assembly IIC operation failure: Battery #1</FONT>
0x83053214#-<FONT COLOR=red>Diag Battery assembly IIC operation failure: Battery #2</FONT>
0x83063314#-<FONT COLOR=red>Diag Soft cache memory ECC error or low battery voltage</FONT>
#
#----------------------------------------------------------------------------
#   Other 
#